Class: Google::Apis::ComputeAlpha::RouterBgpPeerBfd

Inherits:
Object
  • Object
show all
Includes:
Google::Apis::Core::Hashable, Google::Apis::Core::JsonObjectSupport
Defined in:
lib/google/apis/compute_alpha/classes.rb,
lib/google/apis/compute_alpha/representations.rb,
lib/google/apis/compute_alpha/representations.rb

Instance Attribute Summary collapse

Instance Method Summary collapse

Constructor Details

#initialize(**args) ⇒ RouterBgpPeerBfd

Returns a new instance of RouterBgpPeerBfd.



35189
35190
35191
# File 'lib/google/apis/compute_alpha/classes.rb', line 35189

def initialize(**args)
   update!(**args)
end

Instance Attribute Details

#min_receive_intervalFixnum

The minimum interval, in milliseconds, between BFD control packets received from the peer router. The actual value is negotiated between the two routers and is equal to the greater of this value and the transmit interval of the other router. If set, this value must be between 1000 and 30000. The default is 1000. Corresponds to the JSON property minReceiveInterval

Returns:

  • (Fixnum)


35131
35132
35133
# File 'lib/google/apis/compute_alpha/classes.rb', line 35131

def min_receive_interval
  @min_receive_interval
end

#min_transmit_intervalFixnum

The minimum interval, in milliseconds, between BFD control packets transmitted to the peer router. The actual value is negotiated between the two routers and is equal to the greater of this value and the corresponding receive interval of the other router. If set, this value must be between 1000 and 30000. The default is 1000. Corresponds to the JSON property minTransmitInterval

Returns:

  • (Fixnum)


35140
35141
35142
# File 'lib/google/apis/compute_alpha/classes.rb', line 35140

def min_transmit_interval
  @min_transmit_interval
end

#modeString

The BFD session initialization mode for this BGP peer. If set to ACTIVE, the Cloud Router will initiate the BFD session for this BGP peer. If set to PASSIVE, the Cloud Router will wait for the peer router to initiate the BFD session for this BGP peer. If set to DISABLED, BFD is disabled for this BGP peer. The default is PASSIVE. Corresponds to the JSON property mode

Returns:

  • (String)


35149
35150
35151
# File 'lib/google/apis/compute_alpha/classes.rb', line 35149

def mode
  @mode
end

#multiplierFixnum

The number of consecutive BFD packets that must be missed before BFD declares that a peer is unavailable. If set, the value must be a value between 5 and 16. The default is 5. Corresponds to the JSON property multiplier

Returns:

  • (Fixnum)


35156
35157
35158
# File 'lib/google/apis/compute_alpha/classes.rb', line 35156

def multiplier
  @multiplier
end

#packet_modeString

The BFD packet mode for this BGP peer. If set to CONTROL_AND_ECHO, BFD echo mode is enabled for this BGP peer. In this mode, if the peer router also has BFD echo mode enabled, BFD echo packets will be sent to the other router. If the peer router does not have BFD echo mode enabled, only control packets will be sent. If set to CONTROL_ONLY, BFD echo mode is disabled for this BGP peer. If this router and the peer router have a multihop connection, this should be set to CONTROL_ONLY as BFD echo mode is only supported on singlehop connections. The default is CONTROL_AND_ECHO. Corresponds to the JSON property packetMode

Returns:

  • (String)


35168
35169
35170
# File 'lib/google/apis/compute_alpha/classes.rb', line 35168

def packet_mode
  @packet_mode
end

#session_initialization_modeString

The BFD session initialization mode for this BGP peer. If set to ACTIVE, the Cloud Router will initiate the BFD session for this BGP peer. If set to PASSIVE, the Cloud Router will wait for the peer router to initiate the BFD session for this BGP peer. If set to DISABLED, BFD is disabled for this BGP peer. The default is DISABLED. Corresponds to the JSON property sessionInitializationMode

Returns:

  • (String)


35177
35178
35179
# File 'lib/google/apis/compute_alpha/classes.rb', line 35177

def session_initialization_mode
  @session_initialization_mode
end

#slow_timer_intervalFixnum

The minimum interval, in milliseconds, between BFD control packets transmitted to and received from the peer router when BFD echo mode is enabled on both routers. The actual transmit and receive intervals are negotiated between the two routers and are equal to the greater of this value and the corresponding interval on the other router. If set, this value must be between 1000 and

  1. The default is 5000. Corresponds to the JSON property slowTimerInterval

Returns:

  • (Fixnum)


35187
35188
35189
# File 'lib/google/apis/compute_alpha/classes.rb', line 35187

def slow_timer_interval
  @slow_timer_interval
end

Instance Method Details

#update!(**args) ⇒ Object

Update properties of this object



35194
35195
35196
35197
35198
35199
35200
35201
35202
# File 'lib/google/apis/compute_alpha/classes.rb', line 35194

def update!(**args)
  @min_receive_interval = args[:min_receive_interval] if args.key?(:min_receive_interval)
  @min_transmit_interval = args[:min_transmit_interval] if args.key?(:min_transmit_interval)
  @mode = args[:mode] if args.key?(:mode)
  @multiplier = args[:multiplier] if args.key?(:multiplier)
  @packet_mode = args[:packet_mode] if args.key?(:packet_mode)
  @session_initialization_mode = args[:session_initialization_mode] if args.key?(:session_initialization_mode)
  @slow_timer_interval = args[:slow_timer_interval] if args.key?(:slow_timer_interval)
end