#state::String

Returns The status of the current value when compared to the warning and alarm levels for the receiving or transmitting transceiver. Possible states include: - OK: The value has not crossed a warning threshold. - LOW_WARNING: The value has crossed below the low warning threshold. - HIGH_WARNING: The value has crossed above the high warning threshold. - LOW_ALARM: The value has crossed below the low alarm threshold. - HIGH_ALARM: The value has crossed above the high alarm threshold. Check the State enum for the list of possible values.

Returns:

  • (::String)

    The status of the current value when compared to the warning and alarm levels for the receiving or transmitting transceiver. Possible states include: - OK: The value has not crossed a warning threshold. - LOW_WARNING: The value has crossed below the low warning threshold. - HIGH_WARNING: The value has crossed above the high warning threshold. - LOW_ALARM: The value has crossed below the low alarm threshold. - HIGH_ALARM: The value has crossed above the high alarm threshold. Check the State enum for the list of possible values.



16197
16198
16199
16200
16201
16202
16203
16204
16205
16206
16207
16208
16209
16210
16211
16212
16213
16214
16215
16216
16217
16218
16219
16220
16221
# File 'proto_docs/google/cloud/compute/v1/compute.rb', line 16197

class InterconnectDiagnosticsLinkOpticalPower
  include ::Google::Protobuf::MessageExts
  extend ::Google::Protobuf::MessageExts::ClassMethods

  # The status of the current value when compared to the warning and alarm levels for the receiving or transmitting transceiver. Possible states include: - OK: The value has not crossed a warning threshold. - LOW_WARNING: The value has crossed below the low warning threshold. - HIGH_WARNING: The value has crossed above the high warning threshold. - LOW_ALARM: The value has crossed below the low alarm threshold. - HIGH_ALARM: The value has crossed above the high alarm threshold.
  module State
    # A value indicating that the enum field is not set.
    UNDEFINED_STATE = 0

    # The value has crossed above the high alarm threshold.
    HIGH_ALARM = 305_363_284

    # The value of the current optical power has crossed above the high warning threshold.
    HIGH_WARNING = 220_984_799

    # The value of the current optical power has crossed below the low alarm threshold.
    LOW_ALARM = 316_659_046

    # The value of the current optical power has crossed below the low warning threshold.
    LOW_WARNING = 338_793_841

    # The value of the current optical power has not crossed a warning threshold.
    OK = 2524
  end
end

#value::Float

Returns Value of the current receiving or transmitting optical power, read in dBm. Take a known good optical value, give it a 10% margin and trigger warnings relative to that value. In general, a -7dBm warning and a -11dBm alarm are good optical value estimates for most links.

Returns:

  • (::Float)

    Value of the current receiving or transmitting optical power, read in dBm. Take a known good optical value, give it a 10% margin and trigger warnings relative to that value. In general, a -7dBm warning and a -11dBm alarm are good optical value estimates for most links.



16197
16198
16199
16200
16201
16202
16203
16204
16205
16206
16207
16208
16209
16210
16211
16212
16213
16214
16215
16216
16217
16218
16219
16220
16221
# File 'proto_docs/google/cloud/compute/v1/compute.rb', line 16197

class InterconnectDiagnosticsLinkOpticalPower
  include ::Google::Protobuf::MessageExts
  extend ::Google::Protobuf::MessageExts::ClassMethods

  # The status of the current value when compared to the warning and alarm levels for the receiving or transmitting transceiver. Possible states include: - OK: The value has not crossed a warning threshold. - LOW_WARNING: The value has crossed below the low warning threshold. - HIGH_WARNING: The value has crossed above the high warning threshold. - LOW_ALARM: The value has crossed below the low alarm threshold. - HIGH_ALARM: The value has crossed above the high alarm threshold.
  module State
    # A value indicating that the enum field is not set.
    UNDEFINED_STATE = 0

    # The value has crossed above the high alarm threshold.
    HIGH_ALARM = 305_363_284

    # The value of the current optical power has crossed above the high warning threshold.
    HIGH_WARNING = 220_984_799

    # The value of the current optical power has crossed below the low alarm threshold.
    LOW_ALARM = 316_659_046

    # The value of the current optical power has crossed below the low warning threshold.
    LOW_WARNING = 338_793_841

    # The value of the current optical power has not crossed a warning threshold.
    OK = 2524